– 331 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
1 3 Number of received digits of ANI
signal from PSTN
NONE
01
31
No data
1 digit
31 digits
20
3
AP number 0
AP number 3
NOTE: AP number (0-3) corresponds to
the AP numbers assigned by CM05
as shown below.
CM31 Y=2 CM05 Y=0
AP number 0: AP number X
AP number 1: AP number Y
AP number 2: AP number Z
AP number 3: AP number W
(X<Y<Z<W)
0
3
Designation of MFC/MF Sender and
Receiver, Caller ID Receiver, Enhanced 911
Sender to each circuit (No. 0-3)
DATA
SENDER RECEIVER
0 No. 0-3 –
1 No. 0, 1 No. 2, 3
2 No. 2, 3 No. 0, 1
3 – No. 0-3
Continued on next page
INITIAL
~
~
~
~
INITIAL
~
CM31