– 411 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM COUNTER DATA
42
: Initial Data
KIND OF SYSTEM COUNTER SETTING DATA REMARKS
07 Number of detected faulty trunks to give MJ
(major) alarm
[Australia Only]
01
99
NONE
1 trunk
99 trunks
No detection
08 Maximum number of trunks to be seized seri-
ally when a designated trunk is busy
(for Private Lines)
01
16
NONE
1 trunk
16 trunks
Not seized
CM12 Y=16
CM35 Y=98
10 Maximum number of digits for Account Code
with OAI (SCF)
01
10
NONE
1 digit
10 digits
10 digits
Maximum number of digits for Account Code
with MP
01
16
NONE
1 digit
16 digits
10 digits
11 Maximum number of digits for Authorization
Code with OAI (ACF)
01
10
NONE
1 digit
10 digits
10 digits
CM08>216: 1
Maximum number of digits for Authorization
Code with MP
01
16
NONE
1 digit
16 digits
10 digits
CM08>216: 0
12 Maximum number of digits for Forced
Account Code with OAI (ACF)
01
10
NONE
1 digit
10 digits
10 digits
CM08>216: 1
Maximum number of digits for Forced
Account Code with MP
01
16
NONE
1 digit
16 digits
10 digits
CM08>216: 0
13 Maximum number of digits for Remote
Access to System (DISA) Code with OAI
(ACF)
01
10
NONE
1 digit
10 digits
10 digits
CM08>217: 1
Maximum number of digits for Remote
Access to System (DISA) Code with MP
01
16
NONE
1 digit
16 digits
10 digits
CM08>217: 0
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~