– 412 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM COUNTER DATA
42
: Initial Data
NOTE: Careful consideration on the data settings is required because incorrect data settings may
cause howler of low-level speech.
Continued on next page
KIND OF SYSTEM COUNTER SETTING DATA REMARKS
14 Number of times of Call
Forwards in Multiple-Call
Forwarding
01
05
NONE
1 time
5 times
5 times
15 Maximum number of calls in queue in each
UCD group for controlling external indicator
or Call Waiting lamp of D
term
01
99
NONE
1 call
99 calls
1 call
16 Maximum number of calls in queue in each
UCD group before busy tone is provided
01
99
NONE
1 call
99 calls
No limit
19 Number of times for recall from MP built-in
modem
01
09
NONE
1 time
9 times
4 times
47
Volume Control of D
term
/Desk Console
(Sending level: Terminal to PBX)
[Europe Only]
NOTE
00
25
31
NONE
–56 dB
0 dB
+8 dB
0 dB
48
Volume Control of D
term
/Desk Console
(Receiving level: PBX to Terminal)
[Europe Only]
NOTE
00
23
31
NONE
–48 dB
0 dB
+16 dB
0 dB
~
~
~
~
~
~
~
~
INITIAL
~~
2 dB
increments
~~
INITIAL
~~
2 dB
increments
~~
CM42