– 413 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM COUNTER DATA
42
: Initial Data
NOTE 1: In case of default setting, the transmission characteristic depends on A-law/µ-law setting of
the SW2-1 switch on MP card.
NOTE 2: For North America and Australia, this command is not effective. The transmission charac-
teristic depends on the nation code.
NOTE 3: A-law/µ-law setting is decided in the following order.
1. Setting of CM04 Y=10
2. Setting by Key ROM
3. Setting of SW2-1 of the MP
Continued on next page
KIND OF SYSTEM COUNTER SETTING DATA REMARKS
66 Transmission characteristic of analog LC
[New Zealand/China/Brazil/Europe]
NOTE 1, NOTE 2
00
01
02
04
NONE
New Zealand
China
Brazil
Europe
Other countries except
for the above
Transmission characteristic of analog LC,
COT
[For EU]
[Series 3400]
NOTE 1, NOTE 2
01
02
04
05
06
07
08
09
NONE
China
Brazil
UK
Austria/Belgium/Den-
mark/Germany/Sweden/
Switzerland/The Nether-
lands
UK (for EU)
Spain (for EU)
Italy (for EU)
South Africa (for EU)
Depends on Nation Code
(CM31 Y=0>0)
INITIAL
INITIAL
NOVEMBER/15/2006
CM42