– 381 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
AMP TRUNK CONTROL
38
: Initial Data
Y
INCOMING/OUTGOING TRUNK
ROUTE No.
AMP PATTERN No.
SETTING DATA
RELATED
COMMAND
DATA MEANING
01 AMP pattern number 00
AMP pattern number 14
X Z Assignment of Gain value
X: AGC (Automatic Gain Control)
0 : 0 dbr
1 : + 4 dbr
2 : – 4 dbr
3 : Through (Assigned by Fixed Gain)
Z: Fixed Gain
0 : 12 dB
1 : 8 dB
2 : 4 dB
3: 0 dB
02
0
1
Echo Canceller function
Through
Normal
03
0
1
Echo Canceller Gain Controller
ON
OFF
04
0
1
Mode selection of Tone Disabler
G164
G165
05
0
1
Detect time of Tone Disabler
0 second
2 seconds
06
0
1
Channel to be connected
Incoming Route: Tie Line
Outgoing Route: C.O. Line
Incoming Route: C.O. Line
Outgoing Route: Tie Line
07
0
1
Timing of AMP trunk connection
When dialing is finished
When answering
NOTE: The data 0 is effective except ISDN
and CCIS trunks.
~