– 387 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
0
03
Timing for Pseudo-
Answer signal sent to
SMDR
20
24
seconds
00 01 02 03 04 05 06 07 08
4 seconds
4 8 12 16 20 24 28 32 36
8 1216202428323640
04
Guard Timing of trunk
release
0.96
1.44
seconds
01 02 03 04 05 06........................13 14
0.48 seconds
0 0.48 0.96 1.44 1.92 2.40 .................... 5.76 6.24
0.48 0.96 1.44 1.92 2.40 2.88 .................... 6.24 6.72
05
Recall Timing for
Non-exclusive Hold/
Call Park
60
64
seconds
01 02 03 ...............................................98 99
4 seconds
0 4 8 ...............................................388
4 8 12 ..............................................392
NOTE: When timer data 99 is assigned, the call is not
recalled.
06
Recall Timing for
Exclusive Hold/
Remote Hold
236
240
seconds
01 02 03 04 05 06........................98 99
4 seconds
0 4 8 12 16 20.......................388
4 8 12 16 20 24.......................392
NOTE: When timer data 99 is assigned, the call is not
recalled.
07
Recall Timing after
station release for call
transfer
24
28
seconds
01 02 03 04 05 06........................29 30
4 seconds
0 4 8 12 16 20.......................112 116
4 8 12 16 20 24.......................116 120
09
Periodic Time Indica-
tion Tone
192
196
seconds
01 02 03 04 05 06........................16 17
32 seconds
32 64 96 128 160 192......................512 544
36 68 100 132 164 196......................516 548