– 388 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
0
11
Attendant Recall of
held call
31.2
33.6
seconds
01 02 03 04 05 06........................13 14
2.4 seconds
0 2.4 4.8 7.2 9.6 12.0 .................... 28.8 31.2
2.4 4.8 7.2 9.6 12.0 14.4 .................... 31.2 33.6
15 16 17 18 19 ........................................ 24
9.6 seconds
28.8 38.4 48.0 57.6 67.2 ..................................... 115.2
38.4 48.0 57.6 67.2 76.8 .................................... 124.8
13
Single digit dialing
time-out (Timing
Start)
4
5
seconds
03 04 05 06 07 08
1 second
234567
345678
14
DTMF signal width of
Out Pulse-Long from
Attendant Console
512
ms.
01 02 03 04 05 06................................. 50
64 ms.
64 128 192 256 320 384.............................. 3200
15
Elapsed time before
Call Forwarding-
Don’t Answer (No
Answer) for internal
call and assisted call
32
36
seconds
01 02 03 04 05 06........................29 30
4 seconds
0 4 8 12 16 20.......................112 116
4 8 12 16 20 24.......................116 120
NOTE: For the timer of the second call forwarding,
see CM41 Y=0>46.
16
Unanswered timing
for ACD/UCD Delay
Announcement and
Attendant Delay
Announcement
32
36
seconds
01 02 03 ........................................................ 30
4 seconds
0 4 8 .........................................................116
4 8 12 ....................................................... 120
Maximum ACD/UCD
call waiting time
before either answer or
abandonment for PEG
count
32
36
seconds
01 02 03 ........................................................ 30
0 4 8 .........................................................116
4 8 12 ....................................................... 120
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
NOVEMBER/15/2006
CM41