EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 853

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 829 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
TIME BLOCK ASSIGNMENT (1)/
MAXIMUM NUMBER OF CALL RECORD ASSIGNMENT
D003
DATA TABLE:
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
0
15
H-Method Number 0
H-Method Number 15
0 -65535: Time Block (second)
=0.5 × Setting Data
23 Maximum number of Immediate Printout Call Record for the
Printer which is set to “17” by CMD001>80/100/120/140
NOTE 1: When the data is set to 1-1000, external alarm of
memory overflow is available, if CM44 2nd da-
ta=3003 or CMEA Y=2>28, 38 is assigned.
NOTE 2: Billing memory clear by CMD102 is required.
See PRECAUTION (1), PRECAUTION (2).
0: Not used
1 : 1 call
1000: 1000 calls
24 Maximum number of Call Record for SMDR which is set to “5”
by CMD001>80/100/120/140
NOTE 1: When the data is set to 1-27000, external alarm of
memory overflow is available, if CM44 2nd da-
ta=3002 or CMEA Y=2>28, 38 is assigned.
NOTE 2: Billing memory clear by CMD102 is required.
See PRECAUTION (1), PRECAUTION (2).
0 : No limitation
1 : 1 call
27000: 27000 calls
26 Maximum number of Local office’s Call Record for Centralized
Billing-CCIS.
NOTE 1: When the data is set to 1-27000, external alarm of
memory overflow is available, if CM44 2nd da-
ta=3000 or CMEA Y=2>28, 38 is assigned.
NOTE 2: Billing memory clear by CMD102 is required.
See PRECAUTION (1), PRECAUTION (2).
0 : Not record
1 : 1 call
27000: 27000 calls
Continued on next page
~
~
~
~
~
~
~
~
DECEMBER/02/2005
CMD003

Table of Contents

Other manuals for NEC UNIVERGE NEAX 2000 IPS

Related product manuals