– 708 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
OAI CONTROL DATA
D7
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
2 Multi-Connection
Announcement service
for MSF
100
(Fixed)
Message number 1000
(Fixed)
Digital Announcement Trunk
card number
NONE No data
3 Waiting timer for RR sig-
nal after starting up MSF/
TMF
00 Setting Timer 000
001
002
003
127
8 seconds
(4 seconds increments)
4 seconds
8 seconds
12 seconds
508 seconds
4 Maximum number of ter-
minals to be in terminal
mode simultaneously for
MSF/TMF
00 Number of terminals to be in
MSF mode from a PB Tele-
phone
00
32
Number of terminals
01 Number of terminals to be in
terminal mode/TMF simulta-
neously per system
00
01
02
03
30
31
32
32 terminals
(2 terminals increments)
2 terminals
4 terminals
6 terminals
60 terminals
62 terminals
63 terminals
5 Office number for OAI 00 – X
XXXX
NONE
Office No.
(Maximum 4 digits)
No data
6 Operation code to start up
MSF/TMF by dialling a
digit code after pressing
an OAI function key
X
XXX
Digit Code (X=0-9, #)
NOTE 4, NOTE 5
128
191
Operation Code for MSF
NOTE 6
192
255
Operation Code for TMF
NOTE 6
NONE No data
Continued on next page
~
~
~ ~
~
~
~
~~
JULY/01/2006
CMD7