– 780 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
SERIAL No./ID CODE/PROGRAM REVISION READ
F8
NOTE 1: The ID code informed from the Registration Server is automatically registered from MAT-
WorX. [North America Only]
NOTE 2: The Special ID Code can be entered when the System ID code is not available due to trouble
with the Registration Server. The Special ID code is effective for 5 days (7200 minutes). If the
exact ID code is not entered within 5 days as the Special ID Code, you will be restricted for
MAT/CAT operation. [North America Only]
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
5MP/AP Program
Revision Read
XX01 XX
XX
D0-DF: LAN Interface No. 00-15
of IP-PAD/SIP card
E0-EF : LAN Interface No.16-31
of IP-PAD/SIP card
FD : Upgraded side of MP
card
[Series 3500]
FE : Outdated side of MP card
[Series 3500]
FF : ACT program of MP
card
XX : AP No. (04-15, 20-31)
01-05 : Operating procedure
4353 Start Code (Fixed Code)
XX02 XXXX SC Number of Program
Name
XX03 XX Official Version
XX04 XXXX Official Revision
(Integral number)
XX05 XX Official Revision
(Decimal point below)
Do the following operation to read out of the program version.
Example: When reading out the program version of IP-PAD
Operation Display
ST COMMAND=
F85 + DE F85>
D001 + DE F85>D001: 4353 (Start Code [Fixed Code])
S F85>D002: 3353 (SC Number of Program Name)
S F85>D003: A1 (Official Version)
S F85>D004: 0001 (Official Revision [Integral number])
S F85>D005: 00 (Official Revision [Decimal point below])