– 230 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-2
13
: Initial Data
Y SETTING DATA
No. MEANING DATA MEANING
35 Send or not ringing signal to the sin-
gle line telephone connected to Ana-
log Port Adapter
0
1
Not sent ringing signal
Send ringing signal
36 Connection of TAPI Adapter 0
1
TAPI station
Ordinary station
Send information of application to
IP
term
/D
term
SP30
0
1
To send
Not sent
NOTE: Set the second data to “0” for D
term
SP30 in spite of the setting data of CM12 Y=48.
37 VMS Soft Key feature
NOTE: Set this data to VMS station
number.
0
1
To provide
Not provided
39 WCS Roaming for Virtual Station of
Visitor PS
[For PCS]
0
1
Available
Not available
NOTE: When using as WCS Roaming for Virtual Station of Visitor PS, this data must be assigned before
data assignment of CM1C for PS station number.
40 Station number assigned by CM11 for
BLF-CCIS
0
1
Other office station
Own office station
41 Register calling number into Redial
key on D
term
when answering the call
0
1
To provide
Not provided
45 Group Call by Pilot Number Dialing 0
1
To provide
Not provided
46 Call Forwarding-Don’t Answer (No
Answer) Timing
[Series 3100]
0
1
As per CM41 Y=0>100, 101/CME6 Y=07, 08
As per CM41 Y=0>01, 15
NOTE: Call Forwarding-Don’t Answer (No Answer) Timing is as follows when second data is set as 0.
When the timer for each station is set up by CME6 Y=07, 08: The timer of CME6 Y=07, 08 is ef-
fective.
When the timer for each station is not set up by CME6 Y=07, 08: The timer of CM41 Y=0>100,
101 is effective.
[Series 3200 R6.2 (R6.2)]
Continued on next page