– 271 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
ACD/UCD GROUP
17
: Initial Data
Y STATION NUMBER (A) SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
1 Pilot station in
ACD/UCD group
X
XXXXXXXX
Station number to
be assigned as Pilot
0
1
Member station
Pilot station
Pilot station and
Member station for
OAI SCF
X
XXXXXXXX
Station number to
be assigned to queu-
ing for SCF
2
3
OAI Member
station (Off Hook
suppressed)
OAI Pilot station
(Monitor Pilot)
CM41 Y=0
CM49
Y=00-10
CM17 Y=2
2 ACD/UCD Group
number
X
XXXXXXXX
Pilot and Member
station numbers
00
15
NONE
ACD/UCD group 00
ACD/UCD group 15
No data
CM44>14XX
CM90 Y=00:
F1280-F1295
3 Display of station
numbers included in
ACD/UCD group
After entering number (A), other station numbers included in the same
ACD/UCD group are displayed one after another.
Example: OPERATION
Station Number (A): +
+
DISPLAY
Station Number (A): Station Number (B)
Station Number (B): Station Number (C)
4 ACD/UCD service
for internal call
X
XXXXXXXX
Pilot station num-
ber of ACD/UCD
group
0
1
Not provided
To provide
5 ACD/UCD service
for C.O./DID
incoming call
0
1
Not provided
To provide
6 ACD/UCD service
for Tie Line incom-
ing call
0
1
Not provided
To provide
7 ACD/UCD service
for DID/Automated
Attendant
0
1
Not provided
To provide
Continued on next page
~ ~~
~
~
DE DE
~
NOVEMBER/15/2006
CM17