– 334 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
500
15
Sending Backward GC signals on DID
MFC call
[Not used in Australia/
North America]
00: Send GI first digit, change over to GA
01: Send GI next digit, change over to GA
02: Not used
03: Send GII, change over to GB
04: Congestion
05: Send GIII next digit
06:
Not used
08:
09: Send GI same digit, change over to GA
10:
Not used
15:
NONE
01
15
No data
Backward GC-1 signal
Backward GC-15 signal
601
15
Received Backward GA signals on DOD
MFC call
[Not used in Australia/
North America]
01: Backward GA-1 signal
15: Backward GA-15 signal
NONE
00
01
02
03
04
05
06
07
08
09
10
15
No data
Send first digit
Send next digit (n+1)
Send last but one digit (n-1)
Address complete, change over GB
Congestion
Send calling partys category No.
Address complete, set up speech
conditions
Send last but two digits (n-2)
Send last but three digits (n-3)
Send last digit
Not used
Continued on next page
~
INITIAL
~ ~
~
~
~
INITIAL
~
~
~
CM31