– 340 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
B 11 Sending duration of Backward signal
[Not used in Australia/
North America]
NOTE: When this data is not assigned,
system continue to send Backward
signal until receiving Forward sig-
nal.
NONE
00
01
12
NOTE
0 ms.
50 ms.
Increment unit: 50 ms.
600 ms.
12 Waiting duration from sending last
Backward signal to sending Pulse Form sig-
nal
[Not used in Australia/
North America]
NOTE: Effective when CM31 Y=A>05 is
assigned.
NONE
00
01
12
200 ms.
0 ms.
50 ms.
Increment unit: 50 ms.
600 ms.
13 Sending duration of Pulse Form signal
[Not used in Australia/
North America]
NOTE: Effective when CM31 Y=A>05 is
assigned.
NONE
00
01
12
200 ms.
0 ms.
50 ms.
Increment unit: 50 ms.
600 ms.
14 Forbidding duration of receiving Forward
signal for sending Pulse Form signal
[Not used in Australia/
North America]
NOTE: Effective when CM31 Y=A>05 is
assigned.
NONE
00
01
12
350 ms.
0 ms.
50 ms.
Increment unit: 50 ms.
600 ms.
Continued on next page
INITIAL
~
~
INITIAL
~
~
INITIAL
~
~
INITIAL
~
~
CM31