– 390 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
0
36
Interval Time between
attempts for Timed
Queue
120
124
seconds
11 12 13 ....................................................... 31
4 seconds
44 48 52 ...................................................... 120
48 52 56 ...................................................... 124
37
Duration of call by
Timed Queue
28
32
seconds
05 06 ................................................................ 31
4 seconds
16 20 ............................................................... 120
20 24 ............................................................... 124
38
Programmable Pause
for Speed Calling-Sys-
tem (System Speed
Dialing)/Speed Call-
ing-Station (Station
Speed Dialing)
1.5
seconds
00 01 02 03 04 05 06 07
1.5 seconds
1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0
NOTE: This pause is available by setting “D” in
CM72, CM74.
39
Timing of un-
answered call after
forwarding to prede-
termined station in
Automated Attendant
32
36
seconds
01 02 ................................................................ 30
4 seconds
0 4 .................................................................116
4 8 ................................................................ 120
41
PBX Dial In ORT
Timer before receiving
any digit
5
6
seconds
01 02 03 ....................................................... 15
1 second
0 1 2 ........................................................ 14
1 2 3 ........................................................ 15
42
Timing of Call For-
warding by Overflow
for TAS Queue
28
32
seconds
01 02 ................................................................ 99
4 seconds
0 4 ................................................................ 392
4 8 ................................................................ 396
43
Dial Tone timeout in
Automated Attendant
14
seconds
01 02 03 ....................................................... 14
1 second
1 2 3 ........................................................ 14