– 397 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
0
104
ORT timer when
establishing tandem
connection to CCIS/
SIP
[Series 3200 R6.2
(R6.2)]
7
seconds
03 04 05 ........................................................ 99
1 second
3 4 5 ......................................................... 99
NOTE: Assign the value which exceeds the maximum
value of timer set by CMA7 Y=10.
105
SPDT Timer after
Hooking
15
seconds
10 11 12 ........................................................ 60
1 second
10 11 12 ........................................................ 60
106
DTMF signal width on
system basis
[Series 3300]
160 ms.
04 05 06 ........................................................ 15
16 ms.
64 80 96 ....................................................... 240
107
Inter-digit Pause on
system basis
[Series 3300]
NONE
01 02 03 04 05 06 07
16/32/48 ms.
64 80 96 128 160 192 240
108
Timing until IP net-
work between Main
Site and Remote Site
is reconnected
[Series 3300]
NONE
00 01 02 ........................................................ 99
1 second
0 1 2 ......................................................... 99
109
ORT timer for ETSI
ISDN Overlap Receiv-
ing
[Series 3300]
6
seconds
03 04 05 ........................................................ 99
1 second
3 4 5 ......................................................... 99
110
Timing until sending
the reverse signal to
the calling PS Station
for connecting the line
[Series 3300]
NONE
01 02 03 ........................................................ 99
4 seconds
4 8 12 ....................................................... 396
111
ORT timer when
sending LCR
[Series 3300]
7
seconds
02 03 04 ........................................................ 15
1 second
2 3 4 ......................................................... 15
NOTE: Second data “02” is available for Series 3600
or later.
Continued on next page
NOVEMBER/15/2006
CM41