– 418 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
PAD DATA (PROGRAMMABLE)
42
[North America/µ-law countries]
Table 2
T/R: Transmit/Receive
+: Gain
–: Loss
NOTE: The second data is set to 0 dB when using PN-CFTC-A card.
Continued on next page
PAD DATA OF B TRUNK (T/R) [dB]
ODT
(4W E&M)
ODT
(2W E&M)
COT/DID/
LDT
DTI/BRT/
PRT/CCT
CFTC
NOTE
IPT/SIP
00
15
00 0/0 0/0 0/0 0/0 0/0
01 0/0 0/0 0/0 –2/–2 –4 (0)/0 0/–16
02 0/0 0/0 0/0 –3/–3 –8/0 0/–4
03 –2/–2 –3/–3 –3/–3 0/–6 +4/0 0/–12
04 –3/–3 0/0 0/0 –3/–8 0/–3 0/–8
05 –12/–11 –6/–6 –6/–6 +3/–3 –4 (0)/–3
06 –16/–11 0/0 0/+5 –6/–6 –8/–3
07 –6/–6 0/0 +3/+3 –8/–8 +4/–3 0/0
08
Not Used
0/–6
Not Used
09 –4 (0)/–6
10 –8/–6
11 +4/6
12 0/–9
13 –4 (0)/–9
14 –8/–9
15 +4/–9
2ND DATA
PATTERNS
~
NOVEMBER/15/2006
CM42