– 439 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
EXTERNAL EQUIPMENT STARTING CONDITIONS
44
The following table shows the interface condition of each external equipment.
EQUIPMENT KIND INTERFACE RELATED COMMAND REMARKS
External tone source ODT Interface CM10/CM14: DA00
CM48 Y=0
Use ODT card
Ground Start by “M” line of ODT
•RA
RB line of ODT for tone
COT Interface + External
Equipment Interface
CM10/CM14
: DA00
: E800-E831
CM44>0
CM48 Y=0
Use COT, DK of MP card/DK00
card
Loop Start by DK of MP card/
DK00
•Tip
Ring of COT for tone
Wake Up Call/Timed
Reminder tone source
ODT Interface CM10/CM14: DB00
CM48 Y=1
Use ODT card
Ground Start by “M” line of ODT
•RA
RB line of ODT for tone
COT Interface + External
Equipment Interface
CM10/CM14: DB00
CM44>01
CM48 Y=1
Use COT, DK of MP card/DK00
card
Loop Start by DK of MP card/
DK00
Speaker Paging COT Interface + External
Equipment Interface
CM10/CM14
: D000-D255
: E800-E831
CM20: A070-A079
CM30 Y=28
•CM35
CM44>02
Use COT, DK of MP card/DK00
card
Loop Start by DK of MP card/
DK00
Radio Paging COT Interface
(Loop Start)
CM10/CM14
: D000-D255
CM20: A070-A073
CM30 Y=28
•CM35
•Use COT card
Loop Start by Tip
Ring of COT
Relay control via D
term
External Equipment Inter-
face
CM10/CM14
: E800-E831
CM44>15
•CM90
Use DK of MP card/DK00 card
CM44