– 442 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
PURPOSE OF PBR/CFT/SDT
45
: Initial Data
NOTE: Set the PBR card number as follows.
00-15: PBR for a system that is not provided Remote PIM over IP feature or a Main site of
Remote PIM over IP feature. (00 is dedicated to built-in PBR of MP card.)
16-45: Built-in PBR for a Remote site (No. 01-30) of Remote PIM over IP feature.
Y PBR/CFT/SDT NUMBER SETTING DATA
RELATED
COMMAND
No. MEANING No. MEANING DATA MEANING
9 Receiving dB
level of PBR
XX Z XX: PBR card number
Built-in PBR of MP
card: 00
PN-8RST: 01-45
NOTE
Z : Circuit number
(0-3)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
NONE
–22.6 dB
–23.3 dB
–24.0 dB
–24.8 dB
–25.8 dB
–27.0 dB
–27.7 dB
–28.3 dB
–29.1 dB
–29.8 dB
–30.6 dB
–31.4 dB
–32.3 dB
–33.7 dB
–34.5 dB
–26.4 dB
–36.4 dB
–37.0 dB
–37.8 dB
–38.6 dB
–39.3 dB
–41.0 dB
–42.0 dB
–43.1 dB
–44.2 dB
–45.5 dB
–46.5 dB
–47.8 dB
–49.1 dB
–50.2 dB
–51.5 dB
–40.1 dB
No data
CM10/CM14>E2XX
CM45