– 461 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK
4A
NOTE 1: Only “0” or “5” is available for the last digit number of minute at the 1st data of CM4A
Y=20-27.
When the following last digit number is assigned, the number is corrected and set as follows:
assigned number corrected to
1-4 0
6-9 5
NOTE 2: For the Default Pattern, see the following pages.
Continued on next page
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
10
11
12
13
Week schedule No. 0
Week schedule No. 1
Week schedule No. 2
Week schedule No. 3
0
1
2
3
4
5
6
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
20
21
22
23
24
25
26
27
NONE
CCC
Time schedule No. 0
Time schedule No. 1
Time schedule No. 2
Time schedule No. 3
Time schedule No. 4
Time schedule No. 5
Time schedule No. 6
Time schedule No. 7
Time schedule No. 0
Data clear
20
21
22
23
24
25
26
27
Time schedule No. 0
Time schedule No. 1
Time schedule No. 2
Time schedule No. 3
Time schedule No. 4
Time schedule No. 5
Time schedule No. 6
Time schedule No. 7
XX ZZ XX: 00-23: Hour
ZZ : 00-55: Minute
NOTE 1
00
01
02
03
NONE
CCC
Day Mode
Night Mode
Mode A
Mode B
Day Mode
Data clear
90 Default pattern 00-63 Tenant No. 00-63 00
01
02
03
NONE
CCC
Default Pattern No. 0
Default Pattern No. 1
Default Pattern No. 2
Default Pattern No. 3
No data
Data clear
NOTE 2
OFF LINE
CM4A