– 535 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
: Initial Data
Y
1ST DATA
2ND DATA
REMARKS
No. MEANING DATA MEANING
21 Terminating Sta-
tion Tenant for
each DID number
during Mode B
000-999:
Number Conver-
sion Block No.
assigned by
CM76 Y=00/90,
CM2A Y=50-52
00
63
NONE
Station Tenant 00
Station Tenant 63
Trunk Tenant
22 Interval of ringing
tone on DID
incoming calls
0
1
2
3
Rering NOTE 2
Special Ringing
Internal Ringing
As per CM35 Y=33
[Other than North America]
0
1
2
3
0.5 seconds ON-0.5 seconds OFF (D
term
)
1 second ON-2 seconds OFF (SLT)
0.5 seconds ON-0.5 seconds OFF
-0.5 seconds ON-1.5 seconds OFF (D
term
)
0.4 seconds ON-0.2 seconds OFF
-0.4 seconds ON-2 seconds OFF (SLT)
1 second ON-2 seconds OFF
(D
term
or SLT)
As per CM35 Y=33 (D
term
or SLT)
[North America Only]
NOTE 1: CM76 Y=22 is effective when CM08>179: 0 or CM08>180: 1.
NOTE 2: For SLT, Internal Ringing is applied. For D
term
, Special Ringing; 0.5 seconds ON-0.5 seconds OFF
[For Australia/Asia/Africa/Europe/Latin America/Middle East/Russia] or 0.25 seconds ON
-0.25 seconds OFF-0.25 seconds ON-0.25 seconds OFF [For EU] is applied.
23 D
term
Ringer Tone
Pattern on DID
incoming calls
[Series 3200
R6.1 (R6.1)]
000-999:
Number Conver-
sion Block No.
assigned by
CM76 Y=00/90,
CM2A Y=50-52
0
1
2
3
4
5
6
7
Ringer Tone Pattern 0
Ringer Tone Pattern 1
Ringer Tone Pattern 2
Ringer Tone Pattern 3
Ringer Tone Pattern 4
Ringer Tone Pattern 5
Ringer Tone Pattern 6
As per CM35 Y=34/164
CM35 Y=34,
164
CM65 Y=40
NOTE: For the Ringer Tone Pattern, see CM65 Y=40.