– 566 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LCR DEVELOPMENT TABLE
8A
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
5000
5255
LCR Pattern No. 000
LCR Pattern No. 255
173 Location number of the
group
00
63
NONE
Location No. 00
Location No. 63
Location No. 00
174 Link reconnect for PC
connections
0
3
2400 IPX
2000 IPS
175 Detouring to the final
route order when SIP
fault (time-out of T1
timer [no answer timer
for calling]) occurs
[Series 3600]
0
1
To provide
Not provided
NOTE: When setting the second data to 0, the detour to the final
order assigned by CM8A Y=0000-0255>1-4 is executed.
176 Calling party number sent
from SIP Trunk
[Series 3600]
00
01
02
08
14
15
Calling party number is not
sent
To send SIP subscriber
number assigned by CM12
Y=12/13
(when no data is set to
CM12 Y=12/13, the calling
party number is not sent)
To send SIP subscriber
number assigned by CM12
Y=46/47
(when no data is set to
CM12 Y=46/47, the calling
party number is not sent)
To send representative
number
To send the station number
without Originating Office
number
To send station number
Continued on next page
~
~
~
~