– 620 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
CCIS CHANNEL DATA/IP TRUNK DATA/SIP TRUNK DATA
A7
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
59 Maximum threshold value of early
arrival packet used for meantime
adjustment for IP trunk
001
100
NONE
1 %
(1 % increments)
100 %
80 %
CMA7 Y=57
NOTE: The meantime is decreased only when the number of early arrival packets exceeds the value set by
CMA7 Y=59 during the interval set by CMA7 Y=57.
60 FAX mode detection timer for IP
trunk
1
2
3
4
5
6
7
Always detect FAX mode
No FAX mode detection
(Voice mode only)
5 minutes
4 minutes
3 minutes
2 minutes
1 minute
NOTE: This data setting is required for preventing detection error of audio packet.
If the audio packet includes the same tone as FAX answer tone, the voice communication may be dis-
connected.