– 635 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
CS/ZT CALLING AREA/PAD DATA ASSIGNMENT
AD
: Initial Data
NOTE: Follow the initial data setting. When you change the data of CMAD Y=04/05/06/07, contact
NEC.
Continued on next page
Y MEANING CS/ZT No.
SETTING DATA
DATA MEANING
04 Receiving sensibility of LCCH
from PS to ZT
[Latin America Only]
NOTE
000-255 01
02
15
40 dB (Faint)
20 dB (Average)
0 dB (Strong)
05 Sending Level of LCCH from CS/
ZT to PS NOTE
01
02
15
•BS01
10 mW, –35 dB (Faint)
10 mW, –15 dB (Average)
10 mW, 0 dB (Strong)
01
02
15
• BS21/BS21A/BS31/BS41
10 mW, –15 dB (Faint)
10 mW, –15 dB (Average)
10 mW, 0 dB (Strong)
01
02
15
•ZT [Latin America Only]
10 mW, –40 dB (Faint)
10 mW, –20 dB (Average)
10 mW, 0 dB (Strong)
06 Receiving sensibility of TCH
from PS to ZT
[Latin America Only]
NOTE
01
02
15
40 dB (Faint)
20 dB (Average)
0 dB (Strong)
JUNE/01/2007
CMAD