– 643 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
CS/ZT CALLING AREA/PAD DATA ASSIGNMENT
AD
Continued on next page
: Initial Data
Y MEANING CS/ZT No.
SETTING DATA
DATA MEANING
32 NOTE 1: The meaning of the second data is different from the master IP-CS and the submaster IP-CS.
• Fixed master mode:
operates as a Master IP-CS without synchronizing with another CS/ZT, even if the CS/ZT that the wireless
synchronization has already provided.
• Non-fixed master mode:
operates as a submaster IP-CS synchronizes with the CS/ZT that the wireless synchronization has already
provided.
• Timing until Submaster IP-CS starts up:
some IP-CSs that are registered as a submaster IP-CS operate as the master IP-CS when the submaster IP-
CS starts up without the master IP-CS starting. To avoid this, the time of submaster IP-CS starting can be
delayed.
NOTE 2: Set the second data 08 usually, to operate the master IP-CS with fixed master mode and to start
the submaster IP-CS with 30 seconds behind.
NOTE 3: Set the initial data to the submaster IP-CS usually.
NOTE 4: Set the data considering the submaster IP-CS stating time to the master IP-CS, since the master
IP-CS operates as a submaster IP-CS when the submaster IP-CS that is associated by CMAD
Y=48 has operated as a master IP-CS.
Example:
To operate the master IP-CS with the fixed master mode when the master IP-CS operates as itself,
and to set the behind time of submaster starting is 42 seconds when the master IP-CS operates as
a submaster IP-CS, set the second data to 09.
Second Data Master IP-CS Submaster IP-CS
01-07 Non-fixed master mode Timing until Submaster IP-CS starts up 42-114 sec-
onds (12 seconds increments)
08 Fixed master mode Timing until Submaster IP-CS starts up 30 seconds
09-14 Fixed master mode Timing until Submaster IP-CS starts up 42-102 sec-
onds (12 seconds increments)
15 Non-fixed master mode Timing until Submaster IP-CS starts up 30 seconds
JULY/01/2006
CMAD