EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 684

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 660 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
PEG COUNT
B0
NOTE 1: Meaning of display (TRUNK STATUS DATA)
XXX=Trunk No.: 000-255
•Y
1
=0; No Trunk Make Busy
1; Trunk Make Busy
2; No trunk card
•Y
2
=0/1; Normal/Fault=Line status (Broken wire/short circuit)
•Y
3
=0; Not used
•Y
4
=0; Not used
•Y
5
=0/1; Normal/Fault=Line status (Metering Burst)
NOTE 2: Meaning of display (TRUNK STATUS DATA)
•Y
1
=1; Indication of Line fault alarm on MN lamp
•Y
2
=1; Indication of Line fault alarm on MJ lamp
•Y
3
=1; Indication of Line fault alarm on Large type ATTCON MN lamp
NOTE 3: The meaning of the data displayed is as shown below.
0: Not started
1: Under measuring
2: Finished
After turning power on or after a system reset, the system starts the PEG COUNT, if the PEG
COUNT start time has not been set.
B01>XXX: Y
1
Y
2
Y
3
Y
4
Y
5
-
B01>600: Y
1
Y
2
Y
3
-
NOVEMBER/15/2006