– 660 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
PEG COUNT
B0
NOTE 1: Meaning of display (TRUNK STATUS DATA)
• XXX=Trunk No.: 000-255
•Y
1
=0; No Trunk Make Busy
1; Trunk Make Busy
2; No trunk card
•Y
2
=0/1; Normal/Fault=Line status (Broken wire/short circuit)
•Y
3
=0; Not used
•Y
4
=0; Not used
•Y
5
=0/1; Normal/Fault=Line status (Metering Burst)
NOTE 2: Meaning of display (TRUNK STATUS DATA)
•Y
1
=1; Indication of Line fault alarm on MN lamp
•Y
2
=1; Indication of Line fault alarm on MJ lamp
•Y
3
=1; Indication of Line fault alarm on Large type ATTCON MN lamp
NOTE 3: The meaning of the data displayed is as shown below.
0: Not started
1: Under measuring
2: Finished
After turning power on or after a system reset, the system starts the PEG COUNT, if the PEG
COUNT start time has not been set.
B01>XXX: Y
1
Y
2
Y
3
Y
4
Y
5
-
B01>600: Y
1
Y
2
Y
3
-
NOVEMBER/15/2006
CMB0