– 664 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
TRAFFIC MEASUREMENT
B1
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA NEANING
8 Setting of traffic mea-
surement for CS/ZT
0 Traffic Measurement
Mode of CS/ZT
0
1
No Measurement
Hourly Measurement
1 Setting Start Time for
Traffic Measurement
of CS/ZT
MMDDHH
NONE
MM: Month (01-12)
DD : Day (01-31)
HH : Hour (00-23)
No data
2 Display data for Traf-
fic Measurement of
CS/ZT
0
1
2
Before the traffic
measurement
During the traffic
measurement
Completed the traffic
measurement
Continued on next page
CMB1