– 693 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
H.323/SIP PROFILE DATA
BA
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
97 Error response code
when the system
receives the incoming
call, but all SIP trunks
are busy
[Series 3600]
00
31
Profile number
for control packet
0
1
7
480 Temporarily
Unavailable
486 Busy Here
503 Service Unavail-
able
CMA7 Y=71
98 Setting of the SIP inter-
face number to query
the DNS server
[Series 3600]
00
31
NONE
LAN interface No. 00
LAN interface No. 31
No data
CMA7 Y=71
CM0A
Y=60-62
CMBA
Y=93-96, 99
NOTE 1: Set SIP interface to query the domain name of SIP server assigned by CM0A Y=93-96.
NOTE 2: For the LAN interface number set by the second data, the IP Address of DNS server for CM0A
Y=60-62 should be set.
NOTE 3: When the setting of this command is changed, SIP card should be initialized or the DNS cache
table should be cleared by CMBA Y=99.
99 Clearing the cache
table
[Series 3600]
00
31
Profile number
for control packet
CCC DNS cache table
clearance
CMA7 Y=71
NOTE: The IP Addresses which were cached for the second data are displayed when the IP Addresses were
cached on DNS cache table.