– 763 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
MAINTENANCE BY MAT/CAT
EC
(c) Hardware Test
(d) Software Test
01 : Idle
02 : Line Lockout
Other than 01, 02: Busy
INDICATION STATUS OF SINGLE LINE TEL. STATUS OF D
term
STATUS OF D
term
IP
00 Terminal is not connected Terminal is not connected or
tip wire is grounded
Terminal is not connected
01 Terminal is connected Terminal is connected Terminal is connected
02 Loop (Short circuit is made on the line) Short circuit is made on the
line
03 Ring wire is grounded Ring wire is grounded
04 LC card is not mounted DLC card is not mounted
05 Test busy Terminal failure
06 DLC card down
07
08 Line failure detect