– 765 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
MAINTENANCE BY MAT/CAT
EC
Office Data Copy for Backup CPU System [Series 3200 R6.1 (R6.1)]
System Data Backup
NOTE 1: You can assign only “0” to the second data. “1” is displayed while the system data is being
copied.
NOTE 2: Backup takes about 90 seconds on On-line mode, or about 1 minute on Off-line mode. While
saving the system data to flash memory, “SYSD” lamp on the MP card flashes.
NOTE 3: Do not turn off or reset the system while “SYSD” lamp on the MP card is flashing.
SDRAM Data Clear [Series 3100]
NOTE 4: Execute the system data backup by CMEC Y=6>0:0 after this data clear.
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
5 Manual office data
copy for Backup
CPU system
0 All office data copy
from active MP to
stand by MP
0
1
3
Start to copy
Now copying
Stand by
NOTE 1
CM43 Y=4
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
6 System data
backup
0 System data backup 0
1
3
Start to save
Now saving
Stand by
NOTE 1
CM43 Y=5
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
7 SDRAM Data
Clear
00 ID registration for
D
term
IP in Auto-
matic Login Mode
all clear
CCC Clear
NOTE 4
OFF LINE
JULY/01/2006
CMEC