– 801 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
SMDR/CIS/PMS FUNCTIONS (2)
D001
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
40
71
Setting of 1st Break Point (BP1) and 2nd Break Point (BP2) for sur-
charge by K-Method
B P 1 B P 2 K - M et hod N o.
40 41 0
42 43 1
44 45 2
46 47 3
48 49 4
50 51 5
52 53 6
54 55 7
56 57 8
58 59 9
60 61 10
62 63 11
64 65 12
66 67 13
68 69 14
70 71 15
NOTE: For example, when BP1 is set to counting No. 8 (BP1=8), the
1st Time Block (TB1) assigned by CMD024 is applied to 1 to
8 counting No. after call start time. And also, when BP2 is set
to 16 (BP2=16), the 2nd Time Block (TB2) assigned by
CMD024 is applied to BP1=1 to 16, and 3rd Time Block
(TB3) is applied to counting No. exceeding BP2 + 1.
0 : No break point
1:
255:
Continued on next page
~
Break point setting position
(counting No.)
~
CMD001