– 59 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
LANGUAGE INDICATED ON D
term
/ATTCON/DESKCON LCD,
PURPOSE OF CALLER ID SENDER, CONNECTION PORT FOR MCI
04
: Initial Data
Y
1ST DATA 2ND DATA
RELATED
COMMAND
DATA MEANING DATA MEANING
11
40
00 A-law/µ-law for the Remote Site
Y=11: Remote Site No. 01
Y=40: Remote Site No. 30
[For EU]
[Series 3200 R6.2 (R6.2)]
0
1
2
3
A-law
µ-law
Not used
Depends on the SW2-1 on PN-
CP24-A/PN-CP24-B/PN-CP24-C/
PN-CP24-D/PN-CP27-A/PN-
CP27-B or the Key ROM (SP-3722
IPS KYUS PROG-A1) on PN-
CP31-A/PN-CP31-B/PN-CP31-C/
PN-CP31-D
NOTE 1: When using PN-CP24-A/PN-CP24-B/PN-CP24-C/PN-CP24-D/PN-CP27-A/PN-CP27-B, set the 2nd
data to 3 and set the A-law/µ-law by the SW2-1.
NOTE 2: When using PN-CP31-A/PN-CP31-B/PN-CP31-C/PN-CP31-D, the system is set to µ-law automatically.
Set the 2nd data to 0 for A-law.
NOTE 3: Set the same value as Main Site (CM04 Y=10). You cannot set both of A-law and µ-law in the same Re-
mote PIM over IP.
NOTE 4: When CM04 Y=10>00 is set to 3, A-law/µ-law setting is decided in the following order.
1. Setting by Key ROM
2. Setting of SW2-1 of the MP
~
~
NOVEMBER/15/2006