– 807 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
SMDR/CIS/PMS FUNCTIONS (2)
D001
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
115 Delay before resending the Selecting Sequence when NAK is
returned on No. 1 Port
0: Not used
1:
255:
116 Delay before resending the text when WATB is returned on No. 1 Port 0 : Not used
1:
255:
118 Guard timer between texts on No. 1 Port 0 : 0-128 ms.
1 : 128-256 ms.
2 : 256-384 ms.
3 : 384-512 ms.
4 : 512-640 ms.
120 Equipment connected to No. 2 Port 0: Not used
4 : Computer 0
5 : Computer 1
16 : Printer 0
17 : Printer 1
24 : MCI
121 Priority for data processing on No. 2 Port 0 : 1st
1: 2nd
122 Message format on No. 2 Port (When 2nd data of CMD001>120 is set
to 4)
0 : No data is sent out
3: SMDR
(NEAX 2400 IMS Format)
4: SMDR
(NEAX 1400 IMS Format)
6 : PMS (IMS Format)
Number of characters per line to be printed out on No. 2 Port (When
2nd data of CMD001>120 is set to 16/17)
0: Not used
2 : 80 characters
Continued on next page
AP00 INITIAL
128 ms. increments
~
AP00 INITIAL
128 ms. increments
~
AP00 INITIAL
AP00 INITIAL
AP00 INITIAL
JULY/01/2006
CMD001