EasyManua.ls Logo

Omron SYSDRIVE MX2 SERIES - Page 79

Omron SYSDRIVE MX2 SERIES
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-12
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
4
Parameter List
Operation mode/acceleration/deceleration function
A092
1st
Acceleration
Time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
10.00 yes yes
s
5-66
A292
2nd
Acceleration
Time 2
10.00 yes yes
A093
1st
Deceleration
Time 2
10.00 yes yes
A293
2nd
Deceleration
Time 2
10.00 yes yes
A094
2-step
Acceleration/
Deceleration
Selection 1
00: Switched via 2CH terminal
01: Switched by setting
02: Enabled only when
switching forward/reverse
00 no no
A294
2-step
Acceleration/
Deceleration
Selection 2
00 no no
A095
2-step
Acceleration
Frequency 1
0.00 to 99.99
100.0 to 400.0 (1000.)
0.00 no no
Hz
A295
2-step
Acceleration
Frequency 2
0.00 no no
A096
2-step
Deceleration
Frequency 1
0.00 no no
A296
2-step
Deceleration
Frequency 2
0.00 no no
A097
Acceleration
Pattern
Selection
00: Linear
01: S shape
02: U shape
03: Reverse-U shape
04: EL-S shape
01 no no
5-68
A098
Deceleration
Pattern
Selection
01 no no
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit
Page

Table of Contents

Related product manuals