4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
4
Parameter List
Frequency adjustment
A101
FI Start
Frequency
0.00 to 99.99
100.0 to 400.0
0.00 no yes
Hz
5-40
A102
FI End
Frequency
0.00 no yes
A103
FI Start Ratio
0. to FI end ratio 20. no yes %
A104 FI End Ratio FI start ratio to 100. 100. no yes %
A105
FI Start
Selection
00: Use Start Frequency
[A101]
01: 0 Hz
00 no yes −
Acceleration/Deceleration
A131
Acceleration
Curve
Parameter
01 (small curve) to 10 (large
curve)
02 no yes
− 5-68
A132
Deceleration
Curve
Parameter
02 no yes
Operation frequency
A141
Operation
Frequency
Selection 1
00: Digital Operator
01: Digital Operator (volume)
*1
02: FV (voltage) input
03: FI (current) input
04: Modbus communication
(Modbus-RTU)
05: Do not set.
07: Pulse train frequency
02 yes no
− 5-70
A142
Operation
Frequency
Selection 2
03 yes no
*1. Enabled when the Digital Operator with Volume 3G3AX-OP01 is connected.
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit
Page