Install the Power, FIM, Temperature Sensor, and Disk Backplane Data Cables
a.
Connect the disk backplane data cable to the motherboard by opening both
side latches and plugging the data cable connector into the motherboard
connector [8].
The motherboard connector side latches will close, locking the disk backplane data cable
connector in place.
b.
Connect the disk backplane data cable to the disk backplane by opening
both side latches and plugging the data cable connector into the disk
backplane connector [7].
The disk backplane connector side latches will close, locking the disk backplane data cable
connector in place.
2.
Install the FIM cable.
a.
Install the FIM cable into the motherboard by opening both side latches and
plugging the FIM connector into the motherboard connector [6].
The motherboard connector side latches will close, locking the FIM cable connector in
place.
b.
Connect the FIM cable to the FIM by plugging the cable connector into the
FIM [5].
c.
Install the FIM into the server.
See “Install the Front Indicator Module” on page 159.
3.
Install the temperature sensor cable.
a.
Route the temperature sensor cable through the left-front chassis sidewall
and install the sensor into the FIM housing [4].
b.
Connect the temperature sensor cable to the disk backplane by plugging the
cable connector into the disk backplane connector [3].
c.
Install the FIM into the server.
See “Install the Temperature Sensor” on page 166.
4.
Install the disk backplane power cable.
a.
Connect the disk backplane power cable to the disk backplane by plugging
the cable connector into the disk backplane connector [2].
Servicing Other Cables 197