8.4 Target Speed Change Function
8-31
Example of operation (1) Speed direct specification, Active table only
Parameter Setting value
Change mode selection 0000H (Active table only)
Change speed
150,000 pps
f
t
f
t
100,000pps
150,000pps
A
1 2
3
1 2 3
B
C
A Speed change request turns on.
B Only the speed of the table 1 is changed to 150,000 pps.
C The speeds of the table 2 and 3 do not change.
Example of operation (2) Speed direct specification, Active table to E-point table
(until the completion of the operation)
Parameter Setting value
Change mode selection 0001H (Active table to E-point table)
Change speed
150,000 pps
f
t
f
t
100,000pps
150,000pps
A
1 2 3 1 2 3
B
A Speed change request turns on.
B
The speeds of all consecutive tables are changed to 150,000