14.3 Trigger Condition Setting
14-9
14.3.3 Trigger Condition Setting (Trigger Mode/Trigger Position)
"Trigger mode" and "Trigger position" in the Trigger condition setting dialog box are set as
follows.
Setting item
Item Description
Trigger mode
Specifying the timing to log data.
Select Description
Single
After the start request, the logging is executed only at the time of
the first trigger detection.
Normal
After the start request, the logging is executed every time the
trigger is detected.
Auto
After requesting the start, the data before the measurement time
will be stored as measurement data from the point of time when
the logging stop is requested.
Trigger position
Trigger positions displayed on the time chart monitor can be specified. They can be set
by the rate of the measurement time. Select any one from the following options.
0, 1/8, 2/8, 3/8, 4/8, 5/8, 6/8, 7/8
0 1/8 2/8 3/8 4/8 5/8 6/8 7/8 1
T T T T T T
T T
Measurement time [EtherCAT communication cycle x Communication cycle magnification x No. of sampling data]
(0.004 s to 1,044,880 s
Trigger position: