Specifications
16-80
16.8.5 Electronic Cam Setting Area
●: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default
Description R W
1
UM 63F90
-UM 63F91
Cam control
synchronous
master axis
cycle
U1
Set the cam control synchronous master cycle.
U1 to U2147483647
1 UM 63F92
Reserved for
system
- -
- -
1 UM 63F93
Cam pattern
number
U1
Set the registered cam pattern number to be used.
1 to 256
1
UM 63F94
-UM 63F95
Cam stroke
amount
U1
Displacement amount upper limit setting for cam
control
U1 to U2147483647
1
UM 63F96
-UM 63F97
Advance
angle
correction
reference
amount
K0
Set the correction reference amount for calculating
the advance angle correction amount when using
the advance angle correction function.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as
below.
pulse: -2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm): -214,748,364.8 to 214,748,364.7 μm
μm (1 μm): -2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -
21,474.83648 to 21,474.83647
inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647
inches
degree (0.1 degree): -214,748,364.8 to
214,748,364.7 degrees
degree (1 degree): -
2,147,483,648 to 2,147,483,647
degrees
Any other settings will be errors.
1
UM 63F98
-UM 63F99
Advance
angle
correction
reference
speed
U100
Set the reference speed for calculating the advance
angle correction amount when using the advance
angle correction function.
Range: 1 to 2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as
below.
pulse: 1 to 2,147,483,647 pps
μm: 1 to 2,147,483,647 μm/s
inch: 0.001 to 2,147,483.647 inch/s
degree: 0.001 to 2,147,483.647 rev/s
(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,
refer to "16.8.1 Configuration of Synchronous Control Setting Area".