EasyManua.ls Logo

Panasonic AFP7MC16EC

Panasonic AFP7MC16EC
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
16-80
16.8.5 Electronic Cam Setting Area
: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default
Description R W
1
UM 63F90
-UM 63F91
Cam control
synchronous
master axis
cycle
U1
Set the cam control synchronous master cycle.
U1 to U2147483647
1 UM 63F92
Reserved for
system
- -
- -
1 UM 63F93
Cam pattern
number
U1
Set the registered cam pattern number to be used.
1 to 256
1
UM 63F94
-UM 63F95
Cam stroke
amount
U1
Displacement amount upper limit setting for cam
control
U1 to U2147483647
1
UM 63F96
-UM 63F97
Advance
angle
correction
reference
amount
K0
Set the correction reference amount for calculating
the advance angle correction amount when using
the advance angle correction function.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as
below.
pulse: -2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm): -214,748,364.8 to 214,748,364.7 μm
μm (1 μm): -2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -
21,474.83648 to 21,474.83647
inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647
inches
degree (0.1 degree): -214,748,364.8 to
214,748,364.7 degrees
degree (1 degree): -
2,147,483,648 to 2,147,483,647
degrees
Any other settings will be errors.
1
UM 63F98
-UM 63F99
Advance
angle
correction
reference
speed
U100
Set the reference speed for calculating the advance
angle correction amount when using the advance
angle correction function.
Range: 1 to 2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as
below.
pulse: 1 to 2,147,483,647 pps
μm: 1 to 2,147,483,647 μm/s
inch: 0.001 to 2,147,483.647 inch/s
degree: 0.001 to 2,147,483.647 rev/s
(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,
refer to "16.8.1 Configuration of Synchronous Control Setting Area".

Table of Contents