13.5 Completion Width
13-9
13.5 Completion Width
It is used to set the timing to turn on the operation done flag allocated to the I/O of FP7 MC
Unit.
The operation done flag turns on when the AMP current value (UM02654 to UM02655) is in
the range of the +/- completion width (pulse) of the target command position after the
completion of the pulse command output.
The completion width is monitored by FP7 MC Unit unlike the position deviation of AMP.
The completion width function is set in the following unit memories.
Axis
no.
Unit
memory
no. (Hex)
Name Default
Unit Description
Axis 1 UM 03257
Completion
width check
time
U0 ms
Specify the width of the completion of command operation.
Range: 0 to 10,000 (ms)
Any other settings will be errors. When "0" is set, the
completion width is not checked.
Axis 2 UM 032D7
: :
Virtual
axis 1
UM 05257
: :
Virtual
axis 32
UM 061D7
Axis 1
UM 0325A
to UM 0325B
Completion
width
U10 pulse
Turns on the completion flag when the AMP current value
[feedback value] becomes wit
hin this completion width after
the movement of a set amount during the positioning
control, JOG operation.
Range: 1 to 2,147,483,647
Any other settings will be errors.
Axis 2
UM 032DA
- UM 032DB
: :
Virtual
axis 1
UM 0525A
to UM 0525B
: :
Virtual
axis 32
UM 061DA
-UM 061DB
ON
OFF
ON
OFF
(UM00090)
(UM00096)
f [pps]
t [ms]
Completion
width
Completion width
check time
Completion width check starts.
Operation done
Busy
Operation done
Position command
AMP current value
Busy