8.4 Target Speed Change Function
8-33
8.4.3 Setting Procedures and Operations (Ratio Specification Method)
Setting procedures and operations of ratio specification method (Override)
When setting the ratio specification, the command speed is immediately reflected in the
specified ratio once the "Ratio specification" in the unit memory is changed.
f
t
50,000pps
100,000pps
200,000pps
Operation speed rate
100(%) 200(%) 50(%) 100(%)
(Note 1): The acceleration time to the change speed and the deceleration time from the change speed follow the
setting values of the active table.
(Note 2): The movement amount does not change when the speed change is performed.
Setting parameters of ratio specification method
The following parameters are used in the target speed change function of the ratio
specification method.
Positioning operation change setting area
Axis no.
memory
no. (Hex)
Name Default Description
Axis 1 UM 00380
Operation
speed rate
U100
All operations relating to axes (positioning, JOG
operation, home return) can be performed at the
specified rate.
Range: 0 to 500 (%) (For single axis control)
0 to 200 (%) (For interpolation control)
Axis 2 UM 00381
: :
Virtual
axis 1
UM 003C0
: :
Virtual
axis 32
UM 003DF