Automatic Operation (Position Control)
8-54
8.9.3 Sample Program (Rewriting Positioning Tables)
The operation for rewriting positioning tables using a user program is mainly divided into five
steps.
Specify the axis number, table number and table size to rewrite the positioning table.
Set the positioning data to be rewritten.
Set the positioning data in the positioning data setting area in buffers.
Execute reading or writing the data in accordance with the requests stored in buffers.
Execute recalculation.
(Note): The sample program on the next page is for rewriting the positioning data of one table from the table number
1 of the axis number 1 for the FP7 MC Unit installed in the slot number 1.
Contents of sample program
Mark Description
Set the axis number, table number and table size to be rewritten.
Set the axis number, table number and table size.
Set the axis number, table number and table size in the unit memory (control area for buffer control).
Set the positioning data (14 words) to be rewritten in an arbitrary area.
Set the positioning data in the unit memory (positioning data setting area in the buffer).
Execute reading and writing the data in accordance with the requests stored in the buffer.
Specify reading or writing in the unit memory (control area for buffer control).
Set request flags in the unit memory (control area for buffer control).
Execute recalculation.
Set the table number and table size to be recalculated in the unit memory (setting parameter control
area).
Request recalculation until it is completes.
Reset the recalculation table size stored in the unit memory (setting parameter control area) to zero.