CMTimeChart Monitor
14-12
14.4 Download to Setting Data to the Unit
The device registration and trigger conditions made by "CMITimeChart" must be downloaded
to FP7 MC Unit. The following procedure is explained on the condition that "CMTimeChart"
has already started on CMI.
1. Select "Online" > "Download Logging Setting ” from the menu bar.
A confirmation message box is displayed.
2. Press the [OK] button.
Downloading the logging setting is executed. Once the download is complete, a
message box is displayed.
When the logging operation is performed, the following message box is displayed.
Confirm that the logging flag is off by the logging monitor function of
"CMTimeChart" and re-execute the download again.
3. Press the [OK] button.