14.5 Start and Stop of Logging Operation
14-17
14.5.3 Logging Operation Diagram
The timing of sampling data by the logging operation of FP7 MC Unit varies according to the
"Trigger mode" (Single / Normal / Auto) set in "CMTimeChart".
When Trigger mode is "Single"
After the logging operation is executed, the data at the point of time when the first trigger
condition is met will be logged and stored as data.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(UM 02630_bit0)
(UM 02631_bit0)
(UM 02632_bit0)
(UM 02633_bit0)
(YB)
(XB)
Announce trigger registration
Allow trigger use
Waveform logging active
annunciation
Trigger detection
Logging flag
Presence/absence of
logging data
Waveform logging enable
Measurement
time
(Note): If the waveform logging enable (YB) flag turns on before turning on "Allow Trigger Use (UM02631)", the
logging operation will not be executed.
(Note)