14.5 Start and Stop of Logging Operation
14-13
14.5 Start and Stop of Logging Operation
14.5.1 Procedures of Start and Stop by "CMTimeChart"
The logging operation of FP7 MC Unit can be operated on "CMTimeChart". The following
procedure is explained on the condition that "CMTimeChart" has already started on CMI.
1. Select "Online" > "Download Logging Setting" from the menu bar.
"Announce Trigger Registration" and "Allow Trigger Use" turn on in the "Logging
Monitor" window.
2. Select "Online" > "Start Logging" from the menu bar.
A confirmation message box appears.
3. Press the [OK] button.
Once a trigger is detected, the logging is started and the logging flag turns on.
Once the logging is finished, the logging flag turns off and the presence/absence
of logging data flag turns on.