3.3 Connection of Servo Amplifier
3-13
3.3 Connection of Servo Amplifier
3.3.1 Connection of Input Signals
For the system which uses the over limit switches and near home switch, connect them to the
I/O connector of Servo Amplifier A6B/A5B.
AMP
Near home
switch
Over limit
switch
Over limit
switch
I/O connector (X4): Allocation of functions at the factory setting
X4 connector
Function at the factory setting
Application
on the FP7 MC Unit side
Name
Pin
no.
Signal name Code Logic
SI1 5
General-purpose
monitor input 5
SI-MON5 A contact
It can be only monitored by the unit
memories.
SI2 7
CW over-travel inhibit
input
POT B contact
Do not allocate POT or NOT.
SI3 8
CCW over-travel
inhibit input
NOT B contact
SI4 9 Near home input HOME A contact It is used as a near home input.
SI5 10 External latch input 1 EXT1 A contact
It can be only monitored by the unit
memories.
SI6 11 External latch input 2 EXT2 A contact
SI7 12
General-purpose
monitor input 3
SI-MON3 A contact It is used as a limit +.
SI8 13
General-purpose
monitor input 4
SI-MON4 A contact It is used as a limit -.
(Note 1): The above table shows the allocation before shipment. It varies according to the setting of PANATERM.
KEY POINTS
When using FP7 MC Unit in combination with Servo Amplifier A6B/A5B, the
general-purpose inputs (SI-MON3 and SI-MON4) are used as limit inputs. For
using the general-purpose monitor inputs (SI-MON3 and SI-MON4) as limit
inputs, the setting of the limit switch should be set to "A: Enabled" in the
"Axis parameter setting" menu of CMI.
The over-travel inhibit inputs (POT, NOT) cannot be used as the limit inputs
on the FP7 MC Unit side. Do not allocate the over-travel inhibit inputs (POT,
NOT) to the I/O connector (X4) of Servo Amplifier A6B/A5B.