14.8 Storage in SD Memory Card
14-27
14.8.2 Setting When Using SD Memory Cards
Make the following settings to store logging data of FP7 MC Unit.
Setting of time data acquisition
When storing logging data of FP7 MC Unit in an SD memory card, the time data of FP7 CPU
Unit is used. For acquiring the time data of FP7 CPU Unit, make the following settings.
1. Select "Options" > "FP7 Configuration" > "CPU configuration" from the
menu bar of FPWIN GR7.
The "CPU Configuration Setting" dialog box appears.
2. Specify the slot number where FP7 MC Unit is installed for "Slot number of
unit to acquire".
3. Change the setting of "When power supply is on" under "Acquisition
timing" to "Set".
A confirmation message box appears.
4. Press the [OK] button.