Specifications
16-38
16.5.5 Current Value Update Data Area
: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default Description R W
1-16 UM 00590
Current value
update
request
H0
Changes "Unit system conversion current
value" managed by FP7 MC Unit to "current
value update coordinate" only when the bit
corresponding to each axis number changes
to 1 from 0. After the change, FP7 MC Unit
clears the corresponding bits to 0
automatically.
bit
Name
Description
0
Axis 1+16n
Current value
update request
0: No change
1: Update the
current value after
unit conversion of
a target axis
1
Axis 2+16n
Current value
update request
2
Axis 3+16n
Current value
update request
3
Axis 4+16n
Current value
update request
4
Axis 5+16n
Current value
update request
5
Axis 6+16n
Current value
update request
6
Axis 7+16n
Current value
update request
7
Axis 8+16n
Current value
update request
8
Axis 9+16n
Current value
update request
9
Axis 10+16n
Current value
update request
10
Axis 11+16n
Current value
update request
11
Axis 12+16n
Current value
update request
12
Axis 13+16n
Current value
update request
13
Axis 14+16n
Current value
update request
14
Axis 15+16n
Current value
update request
15
Axis 16+16n
Current value
update request
17-32 UM 00591
33-48 UM 00592
49-64 UM 00593
Virtual 1-16 UM 00594
Virtual 17-32 UM 00595