Supplementary Functions
13-42
13.12 Connection with Slave Encoder Input Device
13.12.1 Operation of Encoder Input Device
The encoder input device operates as a ring counter.
The count range of a usable encoder input device is unsigned 32 bits (0 to 4,294,967,295 [H
FFFF FFFF]).
Item
Specifications
Operation image
0
4,294,967,295
[H FFFF FFFF]
Roll
over
Count value
Count up Count down
Operation when reaching the
upper limit or lower limit
If the count value exceeds "4,294,967,295", the count value will be "0"
automatically and the count operation will continue. If the count value falls
below "0", the count value will return to "4,294,967,295" automatically and the
count operation will continue.
REFERENCE
For details of the specifications and setting method of encoder, refer to the
specification sheet and manual of the encoder. Encoder that operation
check has done: GX-EC0211 [Encoder input terminal] made by OMRON