Specifications
16-48
16.5.13 System Operation Setting Area
●: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default Description R W
- UM 0261D
Deceleration
stop
operation
H0
Specify the operation when setting the
deceleration stop request signal to “Active”
(from off to on).
0: Deceleration stop
When performing the repeat operation, stops
after reaching E
-point that is targeted for the
1: Pause
Performs the deceleration stop, and restarts
the positioning operation when turning
“Decele
ration stop request signal” to off from
.
Also, performs the same operation as the
deceleration stop in all states except during
the positioning operation.
When performing the repeat operation, stops
after reaching E
-point that is targeted for the
repeat operation, and restarts the positioning
operation when turning “Deceleration stop
request signal” to
off from on.
If a system stop or emergency stop is
executed while the positioning unit is paused,
the pause state will be canceled and the
operation will not restart with the deceleration
stop request signal is canceled (turned
off).